LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SPOT-235 — PAUSE Bad pressure-both guns

FANUC SPOT-235 (“PAUSE Bad pressure-both guns”): An inavlid binary valve pressure was programmed in the teach pendant program. First check: Check the P= value of the current line of the teach pendant program.

Updated 2026-09-17 · LogrobotLM reference

Description

An inavlid binary valve pressure was programmed in the teach pendant program.

Remedy

Check the P= value of the current line of the teach pendant program. The smallest valve pressure allowed is 0. For digital weld controllers, the largest pressure number allowed depends on the width of the Valve Pressure group output. If this GOUT is 4 I/O points wide, then the maximum pressure is 15. If the GOUT is 5 I/O points wide, then the maximum pressure is 31. For serial weld controllers, the maximum pressure is 15. Re-program the P= value in the teach pendant program.

Related codes