FANUC Alarm SPOT-235 — PAUSE Bad pressure-both guns
FANUC SPOT-235 (“PAUSE Bad pressure-both guns”): An inavlid binary valve pressure was programmed in the teach pendant program. First check: Check the P= value of the current line of the teach pendant program.
Updated 2026-08-29 · LogrobotLM reference
Description
An inavlid binary valve pressure was programmed in the teach pendant program.
Remedy · Remède
Check the P= value of the current line of the teach pendant program. The smallest valve pressure allowed is 0. For digital weld controllers, the largest pressure number allowed depends on the width of the Valve Pressure group output. If this GOUT is 4 I/O points wide, then the maximum pressure is 15. If the GOUT is 5 I/O points wide, then the maximum pressure is 31. For serial weld controllers, the maximum pressure is 15. Re-program the P= value in the teach pendant program.
Frequently asked · Questions fréquentes
- What does FANUC alarm SPOT-235 mean?
- FANUC SPOT-235 (“PAUSE Bad pressure-both guns”): An inavlid binary valve pressure was programmed in the teach pendant program.
- How do you troubleshoot FANUC alarm SPOT-235?
- Check the P= value of the current line of the teach pendant program. The smallest valve pressure allowed is 0. For digital weld controllers, the largest pressure number allowed depends on the width of the Valve Pressure group output. If this GOUT is 4 I/O points wide, then the maximum pressure is 15. If the GOUT is 5…
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →