FANUC Alarm SPOT-245 — PAUSE Bad Pressures (EP=…)-both guns
Manufacturer wording — PAUSE Bad Pressures (EP=%s)-both guns
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC SPOT-245 (“PAUSE Bad Pressures (EP=…)-both guns”): An inavlid binary equalization pressure was programmed in the teach pendant program. First check: Check the EP= value of the current line of the teach pendant program.
Updated 2026-09-17 · LogrobotLM reference
Description
An inavlid binary equalization pressure was programmed in the teach pendant program.
Remedy
Check the EP= value of the current line of the teach pendant program. The smallest valve pressure allowed is 0. For digital weld controllers, the largest pressure number allowed depends on the width of the Equalization Pressure group output. If this GOUT is 4 I/O points wide, then the maximum pressure is 15. If the GOUT is 5 I/O points wide, then the maximum pressure is 31. For serial weld controllers, the maximum pressure is 15. Re-program the EP= value in the teach pendant program.
Related codes