FANUC Alarm SRVO-238 — SERVO Chain 1 (SVON) abnormal
FANUC SRVO-238 (“SERVO Chain 1 (SVON) abnormal”): A single chain 1 (+24V) failure occurred when the SVON (Servo ON/OFF switch) input was asserted. First check: Repair the circuit of chain 1 (+24V) on the SVON hardware.
Updated 2026-09-17 · LogrobotLM reference
Description
A single chain 1 (+24V) failure occurred when the SVON (Servo ON/OFF switch) input was asserted.
Remedy
Repair the circuit of chain 1 (+24V) on the SVON hardware. Set CHAIN FAILURE detection to TRUE on the SYSTEM/CONFIG screen. Press RESET on the teach pendant.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →