FANUC Alarm SYST-006 — WARN KCL is the master device
FANUC SYST-006 (“WARN KCL is the master device”): The attempted operation could not be done be KCL is the master device. First check: Turn the REMOTE switch to local (if the operation is attempted from the SOP), or set the $RMT_MASTER system variable correctly.
Updated 2026-08-29 · LogrobotLM reference
Description
The attempted operation could not be done be KCL is the master device.
Remedy · Remède
Turn the REMOTE switch to local (if the operation is attempted from the SOP), or set the $RMT_MASTER system variable correctly. Refer to the SYSTEM RJ-2 Software Reference Manual, Chapter 2 "System Variables", for more information on system variables.
Frequently asked · Questions fréquentes
- What does FANUC alarm SYST-006 mean?
- FANUC SYST-006 (“WARN KCL is the master device”): The attempted operation could not be done be KCL is the master device.
- How do you troubleshoot FANUC alarm SYST-006?
- Turn the REMOTE switch to local (if the operation is attempted from the SOP), or set the $RMT_MASTER system variable correctly. Refer to the SYSTEM RJ-2 Software Reference Manual, Chapter 2 "System Variables", for more information on system variables.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →