FANUC Alarm SYST-287 — Not enough memory to increase frames
FANUC SYST-287 (“Not enough memory to increase frames”): There is not enough memory to support the number of requested frames. First check: $SCR.$MAXNUMUFRAM and $SCR.$MAXNUMUTOOL have been reset to the number of frames that were able to be configured.
Updated 2026-09-17 · LogrobotLM reference
Description
There is not enough memory to support the number of requested frames.
Remedy
$SCR.$MAXNUMUFRAM and $SCR.$MAXNUMUTOOL have been reset to the number of frames that were able to be configured. However, this is an indicator that controller memory is at a critically low state. A review of option content should be made and controller memory increased if required.
Related codes