LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SYST-287 — Not enough memory to increase frames

FANUC SYST-287 (“Not enough memory to increase frames”): There is not enough memory to support the number of requested frames. First check: $SCR.$MAXNUMUFRAM and $SCR.$MAXNUMUTOOL have been reset to the number of frames that were able to be configured.

Updated 2026-09-17 · LogrobotLM reference

Description

There is not enough memory to support the number of requested frames.

Remedy

$SCR.$MAXNUMUFRAM and $SCR.$MAXNUMUTOOL have been reset to the number of frames that were able to be configured. However, this is an indicator that controller memory is at a critically low state. A review of option content should be made and controller memory increased if required.

Related codes