LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm TG-013 — Invalid IO Port in Sch… Ev…

Manufacturer wording — Invalid IO Port in Sch%d^2 Ev%d^3
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC TG-013 (“Invalid IO Port in Sch… Ev…”): In the trigger schedule number $TGSCHED[num] indicated by the alarm text, the indicated event number has an invalid port type specified. First check: Change $TGSCHED[Sch].$PORT_TYPE[Ev] to a valid port type.

Updated 2026-09-17 · LogrobotLM reference

Description

In the trigger schedule number $TGSCHED[num] indicated by the alarm text, the indicated event number has an invalid port type specified.

Remedy

Change $TGSCHED[Sch].$PORT_TYPE[Ev] to a valid port type. Note that Robot Digital Input and Group Input are not allowed. If you have not modified these variables since loading, then obtain a file backup and contact your FANUC or FANUC Robotics Technical Representative.

Related codes