FANUC Alarm TG-016 — Bad Time Before in Sch… Ev…

Manufacturer wording — Bad Time Before in Sch%d^2 Ev%d^3
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC TG-016 (“Bad Time Before in Sch… Ev…”): The indicate trigger schedule event in $TGSCHED[Sch] has an invalid value for time before. First check: The time before (or anticipator) value cannot be less than (i.e.

Updated 2026-09-17 · LogrobotLM reference

Description

The indicate trigger schedule event in $TGSCHED[Sch] has an invalid value for time before.

Remedy

The time before (or anticipator) value cannot be less than (i.e. more negative than) -100 msec. Check all anticipator values defined in the application to be sure none indicate a time after (i.e. negative time before) greater in magnitude than 100 msec.