LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm VARS-063 — … CMOS lost/reallocated

Manufacturer wording — [%s]%s CMOS lost/reallocated
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC VARS-063 (“… CMOS lost/reallocated”): The CMOS memory for the named variable was corrupted. First check: The named variable will be set to Uninitialized in the process and might need to be set back to a valid initial value.

Updated 2026-09-17 · LogrobotLM reference

Description

The CMOS memory for the named variable was corrupted. This named variable was reallocated as a result of the corruption.

Remedy

The named variable will be set to Uninitialized in the process and might need to be set back to a valid initial value. In general, the only way to recover is an initial start.

Related codes