KUKA Error 1124 — WRONG START POSITION
ErrorDisplayed as KSS01124 on KRC4 / KRC5 controllers
KUKA 1124 (“WRONG START POSITION”): The PAL calibration does not start before the notch but inside it. First check: Move the axis to be calibrated into the correct start position.
Updated 2026-09-09 · LogrobotLM reference
Cause
The PAL calibration does not start before the notch but inside it. The cable for PAL calibration is connected to "localization" or "sensor calibration".
Effect
Stop via braking ramp. All active commands inhibited.
Troubleshooting
Move the axis to be calibrated into the correct start position. Any incorrectly connected cable for PAL calibration must be unplugged.