KUKA Error 1228 — KPS600 / ballast resistor
InfoDisplayed as KSS01228 on KRC4 / KRC5 controllers
KUKA 1228 (“KPS600 / ballast resistor”): The brake chopper remained switched on for too long (I²t of the braking resistor exceeded): excessive braking energy, ballast resistor out of tolerance, or defective ballast stage of the KPS600 that remains conducting. Likely part: KPS600 (KUKA Power Supply 600 — supply & brake ballast).
Updated 2026-09-09 · LogrobotLM reference
Cause
The brake chopper remained switched on for too long (I²t of the braking resistor exceeded): excessive braking energy, ballast resistor out of tolerance, or defective ballast stage of the KPS600 that remains conducting.
Part to check / replace
KUKA 1228 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.