ABB Error 10005 — Program stopped
Error / Erreur🇫🇷 Program stopped
ABB — CATALOGUE PRODUCTION
ABB 10005 (“Program stopped”): Program stopped — ABB robot hardware event on the Program stopped (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Program stopped — ABB robot hardware event on the Program stopped (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
This code's manufacturer text exists only in French in the ABB manuals it comes from. It is reproduced verbatim above; your robot's own manual remains authoritative. ``` The task instance … has stopped. The reason code is …. This means that …: 15001: the task has reached an exit statement 15002: the task is ready 15003: the task is ready with this step 15004: the task has reached a break statement 15005: an external or internal stop has occurred 15006: an error has occurred 15007: Cannot execute backward past beginning of statement list 15008: Cannot execute backward past structured statement 10007: Program started The task instance … has started the execution. The originator is …. 10008: Program restarted The task instance … has restarted the execution. The originator is …. 10009: Program heap full Memory overflow in program instance …. Check: Save the program then restart it. 10010: Motors off state ............................. Chapter 5 10011: Motors on state .............................. Chapter 5 10012: Guard stop state ............................. Chapter 5 Run chain opened by any safety guard except the emergency stop. 10013: Emergency
What to check · Que vérifier
- Inspect the Program stopped, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
Frequently asked · Questions fréquentes
- What does ABB error 10005 mean?
- ABB 10005 (“Program stopped”): Program stopped — ABB robot hardware event on the Program stopped (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 10005?
- Inspect the Program stopped, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →