ABB Error 10354 — Restore aborted due to lost system data.
Error / Erreur🇫🇷 Restore aborted due to lost system data.
ABB — CATALOGUE PRODUCTION
ABB 10354 (“Restore aborted due to lost system data.”): Restore aborted due to lost system data.
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Restore aborted due to lost system data. — ABB robot hardware event on the Restore aborted due to lost system data. (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The system is using a backup of the system data, since the system data was not properly saved at last shutdown. Due to this, a previously ordered Restore from directory arg was attempted again, but was aborted. No RAPID programs or modules will be loaded. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Restore aborted due to lost system data., its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The system data was not properly saved at last shutdown.
- After recovering from the system data loss by a (B)ackup-Restart or system re-installation, please verify that the backup directory arg is OK, and perform the Restore again.
Frequently asked · Questions fréquentes
- What does ABB error 10354 mean?
- ABB 10354 (“Restore aborted due to lost system data.”): Restore aborted due to lost system data. — ABB robot hardware event on the Restore aborted due to lost system data. (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 10354?
- Inspect the Restore aborted due to lost system data., its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →