ABB Error 10455Update of RobotWare System error

Error / Erreur

🇫🇷 Update of RobotWare System error

ABB — CATALOGUE PRODUCTION

ABB 10455 (“Update of RobotWare System error”): Update of RobotWare System error — ABB robot hardware event on the Update of RobotWare System error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Update of RobotWare System error — ABB robot hardware event on the Update of RobotWare System error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Update of the current RobotWare System did not complete properly. The current RobotWare system may be in an undefined state and it may need to be repaired. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Update of RobotWare System error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Manually check if all products in the current system have expected versions and then load a backup if desired.
  • Delete and re-install the current RobotWare system.
  • Use disk recovery functionality.

Frequently asked · Questions fréquentes

What does ABB error 10455 mean?
ABB 10455 (“Update of RobotWare System error”): Update of RobotWare System error — ABB robot hardware event on the Update of RobotWare System error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 10455?
Inspect the Update of RobotWare System error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →