LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 110013Application process interrupted

Error / Erreur

🇫🇷 Application process interrupted

ABB — CATALOGUE PRODUCTION

ABB 110013 (“Application process interrupted”): Application process interrupted — ABB robot hardware event on the Application process interrupted (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Application process interrupted — ABB robot hardware event on the Application process interrupted (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg The application process was not terminated properly. arg Eventual post-motion phases were not executed. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Application process interrupted, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : 1.
  • Logical RAPID instructions in a sequence of application movement instructions consuming too much execution time.
  • The last instruction in the sequence of application movement instructions, that does not indicate the sequence end.
  • Remove the logical instructions, that cause the delay, or check, that the last application movement instruction indicates, that it is the last one.

Frequently asked · Questions fréquentes

What does ABB error 110013 mean?
ABB 110013 (“Application process interrupted”): Application process interrupted — ABB robot hardware event on the Application process interrupted (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 110013?
Inspect the Application process interrupted, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →