LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 110312Wrong number of DAPROC tasks

Error / Erreur

🇫🇷 Wrong number of DAPROC tasks

ABB — CATALOGUE PRODUCTION

ABB 110312 (“Wrong number of DAPROC tasks”): Wrong number of DAPROC tasks — ABB robot hardware event on the Wrong number of DAPROC tasks (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Wrong number of DAPROC tasks — ABB robot hardware event on the Wrong number of DAPROC tasks (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg Error from arg . arg DA\_PROC task(s) are configured in the system. Number of daprocs must be in the interval 1 - arg . arg Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Wrong number of DAPROC tasks, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Check the configuration.

Frequently asked · Questions fréquentes

What does ABB error 110312 mean?
ABB 110312 (“Wrong number of DAPROC tasks”): Wrong number of DAPROC tasks — ABB robot hardware event on the Wrong number of DAPROC tasks (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 110312?
Inspect the Wrong number of DAPROC tasks, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →