ABB Error 110648Invalid deflection time

Error / Erreur

🇫🇷 Invalid deflection time

ABB — CATALOGUE PRODUCTION

ABB 110648 (“Invalid deflection time”): Invalid deflection time — ABB robot hardware event on the Invalid deflection time (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Invalid deflection time — ABB robot hardware event on the Invalid deflection time (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg The value of the deflection time parameter in gundata {arg} is invalid. Allowed values are: > 0 to max arg s. Current value: arg s. Current gun: arg The instruction will not work until this value is changed. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Invalid deflection time, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : A too high gun deflection time has been specified in gundata{arg}.
  • Check the value of the deflection time parameter in gundata {arg}.

Frequently asked · Questions fréquentes

What does ABB error 110648 mean?
ABB 110648 (“Invalid deflection time”): Invalid deflection time — ABB robot hardware event on the Invalid deflection time (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 110648?
Inspect the Invalid deflection time, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →