LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 110672Weld program GO limit

Error / Erreur

🇫🇷 Weld program GO limit

ABB — CATALOGUE PRODUCTION

ABB 110672 (“Weld program GO limit”): Weld program GO limit — ABB robot hardware event on the Weld program GO limit (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Weld program GO limit — ABB robot hardware event on the Weld program GO limit (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg The weld program number is out of limits for the defined weld program group output (GO). Current value: arg . It will not be possible to run any spot instructions until this value is changed. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Weld program GO limit, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The weld program signal group size is smaller than the specified weld program.
  • Increase the size of the weld program output group.
  • Decrease the weld program number.

Frequently asked · Questions fréquentes

What does ABB error 110672 mean?
ABB 110672 (“Weld program GO limit”): Weld program GO limit — ABB robot hardware event on the Weld program GO limit (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 110672?
Inspect the Weld program GO limit, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →