LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 110674Gun type error

Error / Erreur

🇫🇷 Gun type error

ABB — CATALOGUE PRODUCTION

ABB 110674 (“Gun type error”): Gun type error — ABB robot hardware event on the Gun type error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Gun type error — ABB robot hardware event on the Gun type error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg This routine can not be used with this type of gun. Current gun type: arg . It will not be possible run this instruction with this gun type is used. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Gun type error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The gun type parameter in the gun equipment configuration is not set correctly.
  • Check that the gun type parameter is set to the correct type before running this routine.
  • Configuration - Process - Spot Gun Equipment Possible gun types: Servo gun or Pneumatic gun

Frequently asked · Questions fréquentes

What does ABB error 110674 mean?
ABB 110674 (“Gun type error”): Gun type error — ABB robot hardware event on the Gun type error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 110674?
Inspect the Gun type error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →