LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 111117Uplink message failed

Error / Erreur

🇫🇷 Uplink message failed

ABB — CATALOGUE PRODUCTION

ABB 111117 (“Uplink message failed”): Uplink message failed — ABB robot hardware event on the Uplink message failed (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Uplink message failed — ABB robot hardware event on the Uplink message failed (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The system failed to send a process uplink message. Item targets may not be picked. The system may not run as expected. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Uplink message failed, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : Network interrupt.
  • CPU overload in controller system.
  • CPU overload in remote system.
  • Remote system may not run as expected.
  • Check network connection.

Frequently asked · Questions fréquentes

What does ABB error 111117 mean?
ABB 111117 (“Uplink message failed”): Uplink message failed — ABB robot hardware event on the Uplink message failed (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 111117?
Inspect the Uplink message failed, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →