LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 111120Activation of UseReachableTargets failed

Error / Erreur

🇫🇷 Activation of UseReachableTargets failed

ABB — CATALOGUE PRODUCTION

ABB 111120 (“Activation of UseReachableTargets failed”): Activation of UseReachableTargets failed — ABB robot hardware event on the Activation of UseReachableTargets failed (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Activation of UseReachableTargets failed — ABB robot hardware event on the Activation of UseReachableTargets failed (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Activation of UseReachableTargets failed for conveyor arg . The target release zone will be defined by the static enter and exit limits. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Activation of UseReachableTargets failed, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The "Reach zone accuracy" is set too low.
  • Increase the system parameter "Reach zone accuracy".
  • Topic "Process", type "Conveyor systems".
  • Recommended value is 100.

Frequently asked · Questions fréquentes

What does ABB error 111120 mean?
ABB 111120 (“Activation of UseReachableTargets failed”): Activation of UseReachableTargets failed — ABB robot hardware event on the Activation of UseReachableTargets failed (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 111120?
Inspect the Activation of UseReachableTargets failed, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →