LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 111806Computer WDU fault

Error / Erreur

🇫🇷 Calculateur WDU

PROCESS : SOUDAGE WDU (11xxxx) & PEINTURE CBS (13xxxx)

ABB 111806 (“Computer WDU fault”): Computer WDU fault — ABB robot hardware event on the computer WDU (WDU (Soudage)). Likely part: Calculateur WDU (computer WDU).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Computer WDU fault — ABB robot hardware event on the computer WDU (WDU (Soudage)). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Défaut d'écriture/lecture de la mémoire vive interne RAM de la carte logique WDU.

What to check · Que vérifier

  • Inspect the computer WDU, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Mettre l'automate hors tension et rallumer.
  • Remplacer la carte logique si persistant.
  • À savoir : Équivalent aux défauts de mémoire vive RWM (510-2) sur S2/S3 ou 32301 sur S4.

Part to check / replace · Pièce à contrôler / remplacer

ABB 111806 points to the hardware below — start here before ordering. · 111806 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 111806 mean?
ABB 111806 (“Computer WDU fault”): Computer WDU fault — ABB robot hardware event on the computer WDU (WDU (Soudage)). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 111806?
Inspect the computer WDU, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 111806?
111806 points to Calculateur WDU (computer WDU). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →