ABB Error 111957 — No active project
Error / Erreur🇫🇷 No active project
ABB — CATALOGUE PRODUCTION
ABB 111957 (“No active project”): No active project — ABB robot hardware event on the No active project (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
No active project — ABB robot hardware event on the No active project (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Task: arg Instruction/function arg has detected that the project has been stopped. The RAPID can not continue its execution without an active project. Program Ref:arg The program execution is immediately halted. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the No active project, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : - 1) Project has been stopped.
- - 2) A power fail has occurred, and the RAPID program has been started without starting the project again.
- - 3) A warm start has been done, and the RAPID program has been started without starting the project again.
- Start a project.
- In some cases PP must be moved to main.
Frequently asked · Questions fréquentes
- What does ABB error 111957 mean?
- ABB 111957 (“No active project”): No active project — ABB robot hardware event on the No active project (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 111957?
- Inspect the No active project, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →