LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 112201Failed to Open Signal

Error / Erreur

🇫🇷 Failed to Open Signal

ABB — CATALOGUE PRODUCTION

ABB 112201 (“Failed to Open Signal”): Failed to Open Signal — ABB robot hardware event on the Failed to Open Signal (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Failed to Open Signal — ABB robot hardware event on the Failed to Open Signal (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

An error occurred when opening the Error Source Signal. Signal name: arg It will not be possible to set any PickMaster source in an error state. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Failed to Open Signal, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The signal name is not configured in the IO configuration.
  • Verify the Error Source name using the PickMaster PC application.

Frequently asked · Questions fréquentes

What does ABB error 112201 mean?
ABB 112201 (“Failed to Open Signal”): Failed to Open Signal — ABB robot hardware event on the Failed to Open Signal (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 112201?
Inspect the Failed to Open Signal, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →