LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 112350Target configuration outside reach

Error / Erreur

🇫🇷 Target configuration outside reach

ABB — CATALOGUE PRODUCTION

ABB 112350 (“Target configuration outside reach”): Target configuration outside reach — ABB robot hardware event on the Target configuration outside reach (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Target configuration outside reach — ABB robot hardware event on the Target configuration outside reach (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Task: arg A valid robot configuration within reach was not found for target. Program Ref: arg The robot is not able to move to the target position. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Target configuration outside reach, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The target position is outside reach.
  • A robot configuration was not found within reach for the target.
  • Move the target position within the reach of the robot.
  • Check if the target position is possible to reach without robot configuration control (ConfJ\Off, ConfL\Off).
  • Use an error handler and do a RETRY on instruction.

Frequently asked · Questions fréquentes

What does ABB error 112350 mean?
ABB 112350 (“Target configuration outside reach”): Target configuration outside reach — ABB robot hardware event on the Target configuration outside reach (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 112350?
Inspect the Target configuration outside reach, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →