LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 120008Mandatory attribute is missing in cfg file

Error / Erreur

🇫🇷 Mandatory attribute is missing in cfg file

ABB — CATALOGUE PRODUCTION

ABB 120008 (“Mandatory attribute is missing in cfg file”): Mandatory attribute is missing in cfg file — ABB robot hardware event on the Mandatory attribute is missing in cfg file (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Mandatory attribute is missing in cfg file — ABB robot hardware event on the Mandatory attribute is missing in cfg file (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Missing mandatory attribute arg on line arg in file arg . The configuration in file will not be installed. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Mandatory attribute is missing in cfg file, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : Missing/mistyped mandatory attribute.
  • - 1 Re-edit the configuration file.

Frequently asked · Questions fréquentes

What does ABB error 120008 mean?
ABB 120008 (“Mandatory attribute is missing in cfg file”): Mandatory attribute is missing in cfg file — ABB robot hardware event on the Mandatory attribute is missing in cfg file (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 120008?
Inspect the Mandatory attribute is missing in cfg file, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →