LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 120017Invalid Rapid Identifier

Error / Erreur

🇫🇷 Invalid Rapid Identifier

ABB — CATALOGUE PRODUCTION

ABB 120017 (“Invalid Rapid Identifier”): Invalid Rapid Identifier — ABB robot hardware event on the Invalid Rapid Identifier (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Invalid Rapid Identifier — ABB robot hardware event on the Invalid Rapid Identifier (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The value 'arg' of parameter 'arg' for configuration instance 'arg ' is invalid. The configuration in file will not be installed. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Invalid Rapid Identifier, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The value might be mistyped.
  • Correct the value of the parameter so that it complies with the following rules: Rules of RAPID identifiers: The length must not exceed 16 characters.
  • The first character must be a letter (a-z or A-Z).
  • Subsequent characters must be letters (a-z or A-Z), digits (0-9) or underscores (\_).

Frequently asked · Questions fréquentes

What does ABB error 120017 mean?
ABB 120017 (“Invalid Rapid Identifier”): Invalid Rapid Identifier — ABB robot hardware event on the Invalid Rapid Identifier (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 120017?
Inspect the Invalid Rapid Identifier, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →