ABB Error 134225 — Resolver CBS fault
ErrorABB 134225 (“Resolver CBS fault”): Diverging position reported by the internal servo motor resolver and the external CBS resolver. Likely part: Résolveurs CBS (resolver CBS).
Updated 2026-10-22 · LogrobotLM reference
What it means
Diverging position reported by the internal servo motor resolver and the external CBS resolver.
What to check
- Check the axis mechanical coupling and rerun a complete CBS calibration procedure.
- Note: Specific to paint application cabinets with a CBS cartridge changer.
Part to check / replace
ABB 134225 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.