ABB Error 134225 — Resolver CBS fault

Error

ABB 134225 (“Resolver CBS fault”): Diverging position reported by the internal servo motor resolver and the external CBS resolver. Likely part: Résolveurs CBS (resolver CBS).

Updated 2026-10-22 · LogrobotLM reference

What it means

Diverging position reported by the internal servo motor resolver and the external CBS resolver.

What to check

  • Check the axis mechanical coupling and rerun a complete CBS calibration procedure.
  • Note: Specific to paint application cabinets with a CBS cartridge changer.

Part to check / replace

ABB 134225 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →