ABB Error 20195 — System state from last shutdown is lost
Error / Erreur🇫🇷 System state from last shutdown is lost
ABB — CATALOGUE PRODUCTION
ABB 20195 (“System state from last shutdown is lost”): System state from last shutdown is lost — ABB robot hardware event on the System state from last shutdown is lost (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
System state from last shutdown is lost — ABB robot hardware event on the System state from last shutdown is lost (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
Internal system file containing system persistent state was not found. Under normal circumstances, the system state is automatically stored to controller persistent memory during shutdown or restart. The system has been started using auto-recovery system data saved earlier at arg . Any changes made in system configuration or RAPID programs since arg are lost and will have to be re-implemented. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the System state from last shutdown is lost, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The backup energy bank may have been drained at the time of the shutdown.
- The internal storage disk may be full.
- Software problem during shutdown.
- - Check other event messages to help determine the actual cause.
- - If acceptable, acknowledge the auto-recovered system data.
Frequently asked · Questions fréquentes
- What does ABB error 20195 mean?
- ABB 20195 (“System state from last shutdown is lost”): System state from last shutdown is lost — ABB robot hardware event on the System state from last shutdown is lost (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 20195?
- Inspect the System state from last shutdown is lost, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →