LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 20223Emergency stop conflict

Error / Erreur

🇫🇷 Chaîne d'arrêt d'urgence (double canal)

SÉCURITÉ & CHAÎNES CÂBLÉES (20xxx)

ABB 20223 (“Emergency stop conflict”): Emergency stop conflict — ABB robot hardware event on the emergency-stop chain (double canal) (IRC5 / S4C+). Likely part: DSQC 125 (relay / safety board) +1 more.

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Emergency stop conflict — ABB robot hardware event on the emergency-stop chain (double canal) (IRC5 / S4C+). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Emergency stop conflict : un seul des deux canaux de la chaîne d'arrêt d'urgence s'est ouvert. Le système détecte une discordance entre les deux voies redondantes.

What to check · Que vérifier

  • Inspect the emergency-stop chain (double canal), its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Vérifier câbles et connexions de la chaîne ES.
  • Lire les autres messages du journal survenus au même instant pour identifier le contact fautif.
  • Tester chaque interrupteur ES.
  • Remplacer le contact ou le boîtier défaillant.
  • À savoir : Équivalent moderne des défauts de carte à relais DSQC 125/126 des baies S2/S3. Sur Omnicore, remonte via le Safety Controller (9xxxx).

Part to check / replace · Pièce à contrôler / remplacer

ABB 20223 points to the hardware below — start here before ordering. · 20223 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 20223 mean?
ABB 20223 (“Emergency stop conflict”): Emergency stop conflict — ABB robot hardware event on the emergency-stop chain (double canal) (IRC5 / S4C+). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 20223?
Inspect the emergency-stop chain (double canal), its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 20223?
20223 points to DSQC 125 (relay / safety board), Chaîne d'arrêt d'urgence (double canal) (emergency-stop chain (double canal)). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →