ABB Error 20223 — Emergency stop conflict
ErrorABB 20223 (“Emergency stop conflict”): Emergency stop conflict: only one of the two channels of the emergency stop chain has opened. Likely part: DSQC 125 (relay / safety board) +1 more.
Updated 2026-10-22 · LogrobotLM reference
What it means
Emergency stop conflict: only one of the two channels of the emergency stop chain has opened. The system detects a discrepancy between the two redundant channels.
What to check
- Check the cables and connections of the ES chain.
- Read the other log messages that occurred at the same moment to identify the faulty contact.
- Test each ES switch.
- Replace the faulty contact or unit.
- Note: Modern equivalent of the DSQC 125/126 relay board faults of the S2/S3 racks. On OmniCore, reported via the Safety Controller (9xxxx).
Part to check / replace
ABB 20223 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →