ABB Error 20238 — Delayed Superior Stop due to circuit imbalance
Error / Erreur🇫🇷 Delayed Superior Stop due to circuit imbalance
ABB — CATALOGUE PRODUCTION
ABB 20238 (“Delayed Superior Stop due to circuit imbalance”): Delayed Superior Stop due to circuit imbalance — ABB robot hardware event on the Delayed Superior Stop due to circuit imbalance (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Delayed Superior Stop due to circuit imbalance — ABB robot hardware event on the Delayed Superior Stop due to circuit imbalance (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The system has detected an imbalance in the two parallel Superior Stop circuits. The system goes to status Guard Stop after approximately 1 sec. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Delayed Superior Stop due to circuit imbalance, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The contact pair in any of the safety devices connected to the Superior Stop circuit are not working correctly.
- Isolate the safety device causing the conflict.
- Make sure the device used is a two-channel device.
- Check the contact pair.
- Make sure all connections are tight.
Frequently asked · Questions fréquentes
- What does ABB error 20238 mean?
- ABB 20238 (“Delayed Superior Stop due to circuit imbalance”): Delayed Superior Stop due to circuit imbalance — ABB robot hardware event on the Delayed Superior Stop due to circuit imbalance (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
- How do you troubleshoot ABB error 20238?
- Inspect the Delayed Superior Stop due to circuit imbalance, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →