LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 20240Conflict between ENABLE signals

Error / Erreur

🇫🇷 Conflict between ENABLE signals

ABB — CATALOGUE PRODUCTION

ABB 20240 (“Conflict between ENABLE signals”): Conflict between ENABLE signals — ABB robot hardware event on the Conflict between ENABLE signals (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Conflict between ENABLE signals — ABB robot hardware event on the Conflict between ENABLE signals (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

A switch in only one of the two ENABLE chains was affected, without the other chain being affected. The system goes to status SYS HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Conflict between ENABLE signals, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : There may be a loose signal connection on either the contactor board or the panel board.
  • The ENABLE chain is described in the Trouble Shooting Manual and Circuit Diagram.
  • - 1) Check cables and connections.
  • - 2) Make sure all signal connectors on the contactor board and panel board are securely connected.
  • - 3) If there is no loose connection, replace the faulty board.

Frequently asked · Questions fréquentes

What does ABB error 20240 mean?
ABB 20240 (“Conflict between ENABLE signals”): Conflict between ENABLE signals — ABB robot hardware event on the Conflict between ENABLE signals (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 20240?
Inspect the Conflict between ENABLE signals, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →