ABB Error 20253External device temperature high DRV1

Error / Erreur

🇫🇷 Axe externe / Sonde thermique DRV1

ALIMENTATION, CONTACTEURS, FREINS & THERMIQUE MOTEUR (37xxx, 2025x)

ABB 20253 (“External device temperature high DRV1”): External device temperature high DRV1 — ABB robot hardware event on the axis external / thermal sensor DRV1 (IRC5). Likely part: Axe externe / Sonde thermique DRV1 (axis external / thermal sensor DRV1).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

External device temperature high DRV1 — ABB robot hardware event on the axis external / thermal sensor DRV1 (IRC5). Seen across controller generations. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

External device temperature high DRV1 : la surveillance de température du canal d'axe externe DRV1 signale une surchauffe. Se déclenche aussi lorsqu'aucun équipement externe n'est raccordé.

What to check · Que vérifier

  • Inspect the axis external / thermal sensor DRV1, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Vérifier la présence et l'état du bouchon de terminaison sur le connecteur d'axe externe (une terminaison manquante simule un capteur ouvert).
  • Mesurer la chaîne PTC de l'axe externe.
  • Contrôler ventilation et température ambiante de l'armoire.
  • À savoir : Même logique de supervision thermique que 39467 (drive unit) mais côté équipement externe.

Part to check / replace · Pièce à contrôler / remplacer

ABB 20253 points to the hardware below — start here before ordering. · 20253 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 20253 mean?
ABB 20253 (“External device temperature high DRV1”): External device temperature high DRV1 — ABB robot hardware event on the axis external / thermal sensor DRV1 (IRC5). Seen across controller generations. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 20253?
Inspect the axis external / thermal sensor DRV1, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 20253?
20253 points to Axe externe / Sonde thermique DRV1 (axis external / thermal sensor DRV1). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →