LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 37003Power supply logique fault

Error / Erreur

🇫🇷 Alimentation logique

ALIMENTATION, CONTACTEURS, FREINS & THERMIQUE MOTEUR (37xxx, 2025x)

ABB 37003 (“Power supply logique fault”): Power supply logique fault — ABB robot hardware event on the power supply logique (S4/S4C). Likely part: Alimentation logique (power supply logique).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Power supply logique fault — ABB robot hardware event on the power supply logique (S4/S4C). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Tensions d'alimentation électrique +/- 15V du calculateur hors tolérances.

What to check · Que vérifier

  • Inspect the power supply logique, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Vérifier l'unité d'alimentation de l'armoire de commande (Power supply) et les connecteurs physiques.
  • À savoir : Deviendra les pannes d'alimentation logique d'armoire ou de carte CPU d'axes d'IRC5.

Part to check / replace · Pièce à contrôler / remplacer

ABB 37003 points to the hardware below — start here before ordering. · 37003 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 37003 mean?
ABB 37003 (“Power supply logique fault”): Power supply logique fault — ABB robot hardware event on the power supply logique (S4/S4C). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 37003?
Inspect the power supply logique, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 37003?
37003 points to Alimentation logique (power supply logique). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →