ABB Error 20399Static/Semi-static task started

Error / Erreur

🇫🇷 Static/Semi-static task started

ABB — CATALOGUE PRODUCTION

ABB 20399 (“Static/Semi-static task started”): Static/Semi-static task started — ABB robot hardware event on the Static/Semi-static task started (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Static/Semi-static task started — ABB robot hardware event on the Static/Semi-static task started (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

At least one static/semi-static task (alias background task) was not executing after startup in automatic mode. Execution was started in at least one static/semi-static task. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Static/Semi-static task started, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : System was switched to automatic mode during a controller restart.
  • None, system has automatically reset debug settings.
  • To keep debug settings in auto: Switch back to auto mode.
  • Set system parameter Controller/Auto Condition Reset/AllDebugSettings/Reset to NO.
  • Switch back to automatic mode and confirm.

Frequently asked · Questions fréquentes

What does ABB error 20399 mean?
ABB 20399 (“Static/Semi-static task started”): Static/Semi-static task started — ABB robot hardware event on the Static/Semi-static task started (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 20399?
Inspect the Static/Semi-static task started, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →