ABB Error 34252 — Incoming mains missing
ErrorABB 34252 (“Incoming mains missing”): Incoming mains missing: in the drive module, the rectifier in the indicated position detects a loss of the mains voltage. Likely part: Redresseur / Alimentation triphasée (rectifier / power supply three-phase).
Updated 2026-10-22 · LogrobotLM reference
What it means
Incoming mains missing: in the drive module, the rectifier in the indicated position detects a loss of the mains voltage. The system goes to Motors OFF.
What to check
- Measure the incoming mains voltage.
- Check all the internal three-phase components of the drive module: main switch, mains filter, fuses, contactors, and the associated wiring.
- Replace the rectifier if it is faulty.
- Note: Direct successor of “589 REDRESSEUR ABSENT” and “592 TENSION REDRESSEUR” of the S2/S3 racks.
Part to check / replace
ABB 34252 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →