ABB Error 34256 — Rectifier temperature warning
WarningABB 34256 (“Rectifier temperature warning”): Rectifier temperature warning: the rectifier of the drive module is approaching an excessively high temperature level, without having yet reached the cut-off threshold. Likely part: Redresseur / Ventilation (rectifier / cooling).
Updated 2026-10-22 · LogrobotLM reference
What it means
Rectifier temperature warning: the rectifier of the drive module is approaching an excessively high temperature level, without having yet reached the cut-off threshold.
What to check
- Clean or replace the air filters and check that the airflow to the rectifier is not obstructed.
- Check the operation of the cabinet fans.
- Check the ambient temperature and the cycle load.
- Deal with it before the blocking fault appears.
- Note: Warning stage preceding the blocking error 34255. Older equivalent: “593 TEMP. REDRESSEUR” (S2/S3).
Part to check / replace
ABB 34256 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Same hardware involved
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →