ABB Error 34256Rectifier temperature warning

Warning / Avertissement

🇫🇷 Redresseur / Ventilation

ENTRAÎNEMENT : REDRESSEUR, DC-LINK, BLEEDER, ENERGY BANK (34xxx, 36xxx, 386xx S4C+)

ABB 34256 (“Rectifier temperature warning”): Rectifier temperature warning — ABB robot hardware event on the rectifier / cooling (IRC5 / Omnicore). Likely part: Redresseur / Ventilation (rectifier / cooling).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Rectifier temperature warning — ABB robot hardware event on the rectifier / cooling (IRC5 / Omnicore). Seen across controller generations. Severity: Warning. Field diagnosis below (French); your robot's own manual remains authoritative.

Rectifier temperature warning : le redresseur du module d'entraînement approche d'un niveau de température trop élevé, sans avoir encore atteint le seuil de coupure.

What to check · Que vérifier

  • Inspect the rectifier / cooling, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Nettoyer ou remplacer les filtres à air et vérifier que le flux d'air vers le redresseur n'est pas obstrué.
  • Contrôler le fonctionnement des ventilateurs d'armoire.
  • Vérifier la température ambiante et la charge du cycle.
  • Traiter avant l'apparition du défaut bloquant.
  • À savoir : Palier d'alerte précédant l'erreur bloquante 34255. Équivalent ancien : « 593 TEMP. REDRESSEUR » (S2/S3).

Part to check / replace · Pièce à contrôler / remplacer

ABB 34256 points to the hardware below — start here before ordering. · 34256 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 34256 mean?
ABB 34256 (“Rectifier temperature warning”): Rectifier temperature warning — ABB robot hardware event on the rectifier / cooling (IRC5 / Omnicore). Seen across controller generations. Severity: Warning. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34256?
Inspect the rectifier / cooling, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 34256?
34256 points to Redresseur / Ventilation (rectifier / cooling). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Same hardware involved / Même matériel en cause

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →