ABB Error 34256 — Rectifier temperature warning
Warning / Avertissement🇫🇷 Redresseur / Ventilation
ENTRAÎNEMENT : REDRESSEUR, DC-LINK, BLEEDER, ENERGY BANK (34xxx, 36xxx, 386xx S4C+)
ABB 34256 (“Rectifier temperature warning”): Rectifier temperature warning — ABB robot hardware event on the rectifier / cooling (IRC5 / Omnicore). Likely part: Redresseur / Ventilation (rectifier / cooling).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Rectifier temperature warning — ABB robot hardware event on the rectifier / cooling (IRC5 / Omnicore). Seen across controller generations. Severity: Warning. Field diagnosis below (French); your robot's own manual remains authoritative.
Rectifier temperature warning : le redresseur du module d'entraînement approche d'un niveau de température trop élevé, sans avoir encore atteint le seuil de coupure.
What to check · Que vérifier
- Inspect the rectifier / cooling, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Nettoyer ou remplacer les filtres à air et vérifier que le flux d'air vers le redresseur n'est pas obstrué.
- Contrôler le fonctionnement des ventilateurs d'armoire.
- Vérifier la température ambiante et la charge du cycle.
- Traiter avant l'apparition du défaut bloquant.
- À savoir : Palier d'alerte précédant l'erreur bloquante 34255. Équivalent ancien : « 593 TEMP. REDRESSEUR » (S2/S3).
Part to check / replace · Pièce à contrôler / remplacer
ABB 34256 points to the hardware below — start here before ordering. · 34256 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 34256 mean?
- ABB 34256 (“Rectifier temperature warning”): Rectifier temperature warning — ABB robot hardware event on the rectifier / cooling (IRC5 / Omnicore). Seen across controller generations. Severity: Warning. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 34256?
- Inspect the rectifier / cooling, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 34256?
- 34256 points to Redresseur / Ventilation (rectifier / cooling). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →