LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 34258Short circuit in bleeder resistor circuit

Error / Erreur

🇫🇷 Résistance de bleeder / Câble de bleeder

ENTRAÎNEMENT : REDRESSEUR, DC-LINK, BLEEDER, ENERGY BANK (34xxx, 36xxx, 386xx S4C+)

ABB 34258 (“Short circuit in bleeder resistor circuit”): Short circuit in bleeder resistor circuit — ABB robot hardware event on the controller hardware (IRC5 / Omnicore). Likely part: Résistance de bleeder / Câble de bleeder (Résistance de bleeder / Câble de bleeder).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Short circuit in bleeder resistor circuit — ABB robot hardware event on the controller hardware (IRC5 / Omnicore). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Short circuit in bleeder resistor circuit : la résistance de bleeder raccordée au redresseur signale un court-circuit. DANGER HAUTE TENSION : le DC Link ne sera PAS déchargé à la mise hors tension du système.

What to check · Que vérifier

  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Consigner et attendre la décharge avant toute intervention.
  • Vérifier que le câble de bleeder est correctement connecté au redresseur.
  • Déconnecter le bleeder, contrôler le câble et mesurer la valeur de la résistance.
  • Remplacer le câble ou la résistance défaillante.
  • À savoir : Défaut symétrique de 34257 (circuit ouvert du bleeder). Ancien équivalent : « 594 TEMP. RESISTANCE » (S2/S3).

Part to check / replace · Pièce à contrôler / remplacer

ABB 34258 points to the hardware below — start here before ordering. · 34258 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 34258 mean?
ABB 34258 (“Short circuit in bleeder resistor circuit”): Short circuit in bleeder resistor circuit — ABB robot hardware event on the controller hardware (IRC5 / Omnicore). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34258?
Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault. Consigner et attendre la décharge avant toute intervention.
Which part is involved in ABB 34258?
34258 points to Résistance de bleeder / Câble de bleeder (Résistance de bleeder / Câble de bleeder). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →