LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 34264Rectifier inrush limitation active in Motors On

Error / Erreur

🇫🇷 Rectifier inrush limitation active in Motors On

ABB — CATALOGUE PRODUCTION

ABB 34264 (“Rectifier inrush limitation active in Motors On”): Rectifier inrush limitation active in Motors On — ABB robot hardware event on the Rectifier inrush limitation active in Motors On (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Rectifier inrush limitation active in Motors On — ABB robot hardware event on the Rectifier inrush limitation active in Motors On (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

In drive module arg , the inrush control resistor in the rectifier unit at drive unit position arg is wrongly engaged. The system goes to Motors Off state to protect the hardware. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Rectifier inrush limitation active in Motors On, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : This error occur when the DC link voltage becomes too low and all mains phases are missing.
  • Check the hardware event log for other errors.
  • Check incoming mains voltage.
  • Check that the correct voltage is selected with jumpers on the transformer (optional).
  • Check all internal 3-phase components (main switch, mains filter, fuse, contactors) and cabling in the drive module.

Frequently asked · Questions fréquentes

What does ABB error 34264 mean?
ABB 34264 (“Rectifier inrush limitation active in Motors On”): Rectifier inrush limitation active in Motors On — ABB robot hardware event on the Rectifier inrush limitation active in Motors On (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual…
How do you troubleshoot ABB error 34264?
Inspect the Rectifier inrush limitation active in Motors On, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →