ABB Error 34306Drive unit temperature error

Error / Erreur

🇫🇷 Drive unit temperature error

ABB — CATALOGUE PRODUCTION

ABB 34306 (“Drive unit temperature error”): Drive unit temperature error — ABB robot hardware event on the Drive unit temperature error (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Drive unit temperature error — ABB robot hardware event on the Drive unit temperature error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The drive unit for joint arg has reached a too high temperature level. The joint is connected to drive module arg with the drive unit at unit position arg and node arg . No operation will be possible until the fault is corrected. The system goes to Motors Off state. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Drive unit temperature error, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : - 1 The cooling fans may be faulty or the air flow may be obstructed.
  • - 2 The cooling fins are covered by dust reducing the cooling effect.
  • - 3 The ambient temperature may be too high.
  • - 4 The joint may be running with a too high torque for extended periods of time.
  • Verify that the fans are running and that the air flow is not obstructed.

Frequently asked · Questions fréquentes

What does ABB error 34306 mean?
ABB 34306 (“Drive unit temperature error”): Drive unit temperature error — ABB robot hardware event on the Drive unit temperature error (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34306?
Inspect the Drive unit temperature error, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →