ABB Error 34318 — Drive Unit / motor / DC-link fault

Error

ABB 34318 (“Drive Unit / motor / DC-link fault”): The Drive Unit reaches its maximum output voltage: inverter saturation. Likely part: Drive Unit / Moteur / DC-Link (Drive Unit / motor / DC-link).

Updated 2026-10-22 · LogrobotLM reference

What it means

The Drive Unit reaches its maximum output voltage: inverter saturation.

What to check

  • Check motor connection, motor parameters, DC link voltage, phase/ground short circuits and mains voltage; measure cable and motor with power off.
  • Note: Fault often correlated with a motor/cable, DC link or configuration problem. Also observed during service work on additional axes.

Part to check / replace

ABB 34318 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.