LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 34319Drive Unit / cooling fault

Error / Erreur

🇫🇷 Drive Unit / Refroidissement

ENTRAÎNEMENT : REDRESSEUR, DC-LINK, BLEEDER, ENERGY BANK (34xxx, 36xxx, 386xx S4C+)

ABB 34319 (“Drive Unit / cooling fault”): Drive Unit / cooling fault — ABB robot hardware event on the Drive Unit / cooling (IRC5). Likely part: Drive Unit / Refroidissement (Drive Unit / cooling).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Drive Unit / cooling fault — ABB robot hardware event on the Drive Unit / cooling (IRC5). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

Erreur critique non spécifiée de la Drive Unit, typiquement associée à surchauffe ou court-circuit.

What to check · Que vérifier

  • Inspect the Drive Unit / cooling, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Contrôler ventilateurs, dissipateurs, température ambiante, surcharge/couple, accélérations, câbles, connecteurs et moteur.
  • À savoir : Défaut matériel générique de Drive Unit; forte valeur diagnostique lorsqu’il accompagne d’autres erreurs 34xxx.

Part to check / replace · Pièce à contrôler / remplacer

ABB 34319 points to the hardware below — start here before ordering. · 34319 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 34319 mean?
ABB 34319 (“Drive Unit / cooling fault”): Drive Unit / cooling fault — ABB robot hardware event on the Drive Unit / cooling (IRC5). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34319?
Inspect the Drive Unit / cooling, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 34319?
34319 points to Drive Unit / Refroidissement (Drive Unit / cooling). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →