LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

ABB Error 34401 — DC link voltage too low (warning)

Warning

ABB 34401 (“DC link voltage too low (warning)”): DC link voltage too low (warning): in the drive module, the DC link voltage of the indicated drive is close to the minimum limit. Likely part: DC Link / Réseau entrant / Redresseur (DC Link / mains / rectifier).

Updated 2026-10-22 · LogrobotLM reference

What it means

DC link voltage too low (warning): in the drive module, the DC link voltage of the indicated drive is close to the minimum limit. Warning level before the blocking fault.

What to check

  • Measure the incoming mains voltage at the rectifier — the dominant cause is an out-of-specification mains supply (voltage dips, weak phase).
  • If the mains is good, check the internal three-phase components: main switch, mains filter, fuses, contactors, and the module wiring.
  • Note: IRC5 equivalent of 38600 (S4C+, incoming DC link voltage too low) and a relative of 33107 (S4). In bursts on several cabinets simultaneously = electrical installation, not the robots.

Part to check / replace

ABB 34401 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →