LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 34402DC link voltage too low

Error / Erreur

🇫🇷 DC link voltage too low

ABB — CATALOGUE PRODUCTION

ABB 34402 (“DC link voltage too low”): DC link voltage too low — ABB robot hardware event on the DC link voltage too low (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

DC link voltage too low — ABB robot hardware event on the DC link voltage too low (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

In drive module arg , the DC link voltage is too low for the drive unit at unit position arg . No operation will be possible until the fault is corrected. The system goes to Motors Off state. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the DC link voltage too low, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : The incoming mains voltage to the rectifier unit is out of specification.
  • Check for other hardware event log messages regarding mains voltage problem.
  • Check incoming mains voltage.
  • Change the mains tolerance min so that the mains voltage is inside the specified interval.
  • Check that the correct voltage is selected with jumpers on the transformer (optional).

Frequently asked · Questions fréquentes

What does ABB error 34402 mean?
ABB 34402 (“DC link voltage too low”): DC link voltage too low — ABB robot hardware event on the DC link voltage too low (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34402?
Inspect the DC link voltage too low, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →