LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 34405DC link voltage too high warning

Error / Erreur

🇫🇷 DC link voltage too high warning

ABB — CATALOGUE PRODUCTION

ABB 34405 (“DC link voltage too high warning”): DC link voltage too high warning — ABB robot hardware event on the DC link voltage too high warning (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

DC link voltage too high warning — ABB robot hardware event on the DC link voltage too high warning (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

In drive module arg , the drive unit at unit position arg has a DC link voltage that is close to maximum limit. Operation will be possible but the system is close to a stopping error. WARNING HIGH VOLTAGE: THE DC LINK MAY BE DISCHARGED VERY SLOWLY (APPROXIMATELY 1 HOUR) WHEN THE SYSTEM IS POWERED OFF. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the DC link voltage too high warning, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : - 1 The bleeder resistor is not connected or faulty.
  • - 2 The user program may contain too much deceleration of the manipulator's axes.
  • This fault is more likely if the system contains additional axes.

Frequently asked · Questions fréquentes

What does ABB error 34405 mean?
ABB 34405 (“DC link voltage too high warning”): DC link voltage too high warning — ABB robot hardware event on the DC link voltage too high warning (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34405?
Inspect the DC link voltage too high warning, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →