LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 34423Drive units fault

Error / Erreur

🇫🇷 Variateurs

ENTRAÎNEMENT : REDRESSEUR, DC-LINK, BLEEDER, ENERGY BANK (34xxx, 36xxx, 386xx S4C+)

ABB 34423 (“Drive units fault”): Drive units fault — ABB robot hardware event on the Drive units (IRC5/Omnicore). Likely part: DSQC462 (drive unit).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Drive units fault — ABB robot hardware event on the Drive units (IRC5/Omnicore). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.

La baie d'entraînement d'axes contient des modèles de variateurs incompatibles (ex. DSQC462).

What to check · Que vérifier

  • Inspect the Drive units, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Vérifier la configuration logicielle et s'assurer d'insérer des variateurs compatibles d'armoire.
  • À savoir : Équivalent aux incompatibilités de variateurs d'entraînement.

Part to check / replace · Pièce à contrôler / remplacer

ABB 34423 points to the hardware below — start here before ordering. · 34423 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does ABB error 34423 mean?
ABB 34423 (“Drive units fault”): Drive units fault — ABB robot hardware event on the Drive units (IRC5/Omnicore). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
How do you troubleshoot ABB error 34423?
Inspect the Drive units, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Which part is involved in ABB 34423?
34423 points to DSQC462 (drive unit). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →