LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 37044Overload on Panel Board digital output signals

Error / Erreur

🇫🇷 Overload on Panel Board digital output signals

ABB — CATALOGUE PRODUCTION

ABB 37044 (“Overload on Panel Board digital output signals”): Overload on Panel Board digital output signals — ABB robot hardware event on the Overload on Panel Board digital output signals (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Overload on Panel Board digital output signals — ABB robot hardware event on the Overload on Panel Board digital output signals (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

The Panel Board User Digital outputs draw too much current. The Panel Board shuts down the signals, causing the system to go to status SYS HALT. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Overload on Panel Board digital output signals, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • probable : A load connected to the circuit may be too high, or the Panel Board may be malfunctioning.
  • See the Circuit Diagram!
  • - 1) Check all loads connected to the User Digital outputs - 2) Check the Panel Board cabling and connectors, and replace any faulty unit if required.

Frequently asked · Questions fréquentes

What does ABB error 37044 mean?
ABB 37044 (“Overload on Panel Board digital output signals”): Overload on Panel Board digital output signals — ABB robot hardware event on the Overload on Panel Board digital output signals (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 37044?
Inspect the Overload on Panel Board digital output signals, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →