ABB Error 37052 — Power supply ordinateur main / Computer Unit fault
ErrorABB 37052 (“Power supply ordinateur main / Computer Unit fault”): A voltage measured on the main computer is out of tolerance. Likely part: Alimentation ordinateur principal / Computer Unit (power supply ordinateur main / Computer Unit).
Updated 2026-10-22 · LogrobotLM reference
What it means
A voltage measured on the main computer is out of tolerance. Documented case: 3.3 V measured for 3.0 V expected.
What to check
- LOTO.
- Check the Computer Unit power supplies, in particular the power supply board and the logic voltages.
- Also check the loads/connectors and the battery condition; replace/repair the power supply if the voltage remains out of tolerance.
- Note: S4C+ logic power supply fault; to be distinguished from a simple battery warning.
Part to check / replace
ABB 37052 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →