ABB Error 37062 — Computer Module power supply warning
Error / Erreur🇫🇷 Computer Module power supply warning
ABB — CATALOGUE PRODUCTION
ABB 37062 (“Computer Module power supply warning”): Computer Module power supply warning — ABB robot hardware event on the Computer Module power supply warning (IRC5).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Computer Module power supply warning — ABB robot hardware event on the Computer Module power supply warning (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
The arg V voltage of the Computer Module power supply is arg V, which is out of the allowed range. - Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.
What to check · Que vérifier
- Inspect the Computer Module power supply warning, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- probable : The power supply unit, cabling, input voltage to the power supply or the output load may cause the faulty voltage level.
- See the Trouble Shooting Manual and Circuit Diagram!
- - 1) Check all cabling to the power supply unit.
- - 2) Measure the output and input voltage levels.
- - 3) Replace the faulty unit if required.
Frequently asked · Questions fréquentes
- What does ABB error 37062 mean?
- ABB 37062 (“Computer Module power supply warning”): Computer Module power supply warning — ABB robot hardware event on the Computer Module power supply warning (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 37062?
- Inspect the Computer Module power supply warning, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →