LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 37087Purge sensor arg watchdog pulse has stopped.

Error / Erreur

🇫🇷 Purge sensor arg watchdog pulse has stopped.

ABB — CATALOGUE PRODUCTION

ABB 37087 (“Purge sensor arg watchdog pulse has stopped.”): Purge sensor arg watchdog pulse has stopped.

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Purge sensor arg watchdog pulse has stopped. — ABB robot hardware event on the Purge sensor arg watchdog pulse has stopped. (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

Pulses are missing from manipulator interface board (MIB) for the PPSB sensor. Power and communication to the manipulator and equipment located in "Ex p" encapsulated area has been disconnected. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Purge sensor arg watchdog pulse has stopped., its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Check HMI and system status.
  • Check LED status on MIB.
  • Check purge sensors and cabling for purge sensors.

Frequently asked · Questions fréquentes

What does ABB error 37087 mean?
ABB 37087 (“Purge sensor arg watchdog pulse has stopped.”): Purge sensor arg watchdog pulse has stopped. — ABB robot hardware event on the Purge sensor arg watchdog pulse has stopped. (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains…
How do you troubleshoot ABB error 37087?
Inspect the Purge sensor arg watchdog pulse has stopped., its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →