LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

ABB Error 37280Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV

Error / Erreur

🇫🇷 Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV

ABB — CATALOGUE PRODUCTION

ABB 37280 (“Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV”): Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV — ABB robot hardware event on the Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV (IRC5).

Updated 2026-08-29 · LogrobotLM reference

What it means · Ce que ça veut dire

Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV — ABB robot hardware event on the Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV (IRC5). Specific to this controller generation. Severity: Major. Field diagnosis below (French); your robot's own manual remains authoritative.

A fault is observed on activation of atomizing air supply valve. Divergence reported on feedback. The enable chain will be opened if valve did not deactivate. Le texte constructeur de ce code n'existe qu'en anglais dans les manuels ABB dont il provient. Il est reproduit tel quel ci-dessus ; le manuel de votre robot fait foi.

What to check · Que vérifier

  • Inspect the Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV, its wiring and connections first.
  • Match this code against your robot's event-log timeline before swapping parts.
  • Follow the French field checks below — they are the tested sequence for this fault.
  • Check HMI and system status.
  • Check cables and connections.
  • Check valve YV3 and sensor SP4.

Frequently asked · Questions fréquentes

What does ABB error 37280 mean?
ABB 37280 (“Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV”): Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV — ABB robot hardware event on the Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV (IRC5). Specific to this controller generation.…
How do you troubleshoot ABB error 37280?
Inspect the Wrong feedback from YV3 atomizing air, after activation of YV3 A1AtomV, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →